RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0613005032 - Archived data from Wed, 03. February 2021 18:19:54 CET


This is all the information about APD 0613005032. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0613005032
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G13
Break-through voltage: 456 V
Voltage for Gain 100 (T=+25°C): 429.2 V
Dark current: 16.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 46
Position in Box: 37
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 428.8336616 V     T = -25 °C: 392.0119968 V
Voltage for Gain 150: T = +20 °C: 436.6610236 V     T = -25 °C: 399.8037771 V
Voltage for Gain 200: T = +20 °C: 439.111172 V     T = -25 °C: 404.1278717 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.60569038 V-1     T = -25 °C: 4.542815331 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.037049511 V-1     T = -25 °C: 8.904619763 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 11.0839116 V-1     T = -25 °C: 15.4899069 V-1
Break-through voltage: T = +20 °C: 440.0047225 V     T = -25 °C: 415.0046106 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:54:12 CET jreher Updated box and position via API.
03. Feb 2021 18:19:54 CET jreher Updated box and position via API.
07. Oct 2020 15:46:10 CEST jreher Updated APD location via API.
11. Aug 2020 17:27:23 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:37:11 CET jreher Updated APD location via API.
25. Nov 2019 17:14:34 CET jreher Updated box and position via API.
04. Jul 2019 11:11:54 CEST jreher Updated APD location via API.
18. Jun 2019 13:34:38 CEST jgrochowski Updated APD batch assignment via API.
18. Jun 2019 10:18:21 CEST Tobias Imported from Hamamatsu datasheet.