RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3802038592 - Archived data from Tue, 11. August 2020 17:28:47 CEST


This is all the information about APD 3802038592. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3802038592
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F03
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 378.5 V
Dark current: 16.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 50
Position in Box: 21
EP1 batch: 6
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 28. Jun 2019
Sent for analysis after irradiation: 08. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.8558554 V     T = -25 °C: 343.5894413 V
Voltage for Gain 150: T = +20 °C: 385.51767 V     T = -25 °C: 350.7684773 V
Voltage for Gain 200: T = +20 °C: 389.8121601 V     T = -25 °C: 354.7890215 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.826322368 V-1     T = -25 °C: 4.87436613 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.80864931 V-1     T = -25 °C: 10.15190735 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.44292358 V-1     T = -25 °C: 16.53794493 V-1
Break-through voltage: T = +20 °C: 404.7513234 V     T = -25 °C: 369.3058682 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:54:47 CET jreher Updated box and position via API.
03. Feb 2021 18:20:23 CET jreher Updated box and position via API.
11. Aug 2020 17:28:47 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:31:13 CET jreher Updated APD location via API.
25. Nov 2019 17:14:52 CET jreher Updated box and position via API.
15. Jul 2019 13:01:29 CEST spankonin Updated APD batch assignment via API.
08. Jul 2019 11:04:04 CEST markus.moritz
20. Jun 2019 19:34:02 CEST jreher Updated APD location via API.
12. Jun 2019 17:17:32 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 17:14:43 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 17:14:26 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:42:51 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:38:57 CEST jreher Updated APD batch assignment via API.
25. Apr 2019 15:14:56 CEST Tobias Imported from Hamamatsu datasheet.