Subdetector specification:  
Serial: 3708038385
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F03
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 377.2 V
Dark current: 14.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 48
Position in Box: 27
EP1 batch: 3
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 28. Jun 2019
Sent for analysis after irradiation: 08. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 04. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 05. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.0498484 V     T = -25 °C: 342.9077528 V
Voltage for Gain 150: T = +20 °C: 384.7106413 V     T = -25 °C: 350.0093236 V
Voltage for Gain 200: T = +20 °C: 388.9819824 V     T = -25 °C: 353.9986935 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.785673382 V-1     T = -25 °C: 5.197207472 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.715184529 V-1     T = -25 °C: 10.05294936 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.29439822 V-1     T = -25 °C: 16.41965039 V-1
Break-through voltage: T = +20 °C: 404.5381696 V     T = -25 °C: 368.8773722 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:54:32 CET jreher Updated box and position via API.
03. Feb 2021 18:20:08 CET jreher Updated box and position via API.
11. Aug 2020 17:28:33 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:30:52 CET jreher Updated APD location via API.
25. Nov 2019 17:14:43 CET jreher Updated box and position via API.
15. Jul 2019 13:00:52 CEST spankonin Updated APD batch assignment via API.
08. Jul 2019 10:31:55 CEST markus.moritz
20. Jun 2019 18:30:44 CEST jreher Updated APD location via API.
12. Jun 2019 16:42:43 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:41:52 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:38:48 CEST jreher Updated APD batch assignment via API.
25. Apr 2019 15:14:53 CEST Tobias Imported from Hamamatsu datasheet.