Show Hamamatsu Avalanche Photo Diode 3314036307 - Archived data from Fri, 29. November 2019 11:49:27 CET
This is all the information about APD 3314036307. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 3314036307 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Giessen |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F09 |
Break-through voltage: | 408 V |
Voltage for Gain 100 (T=+25°C): | 380.9 V |
Dark current: | 22.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 154 |
Position in Box: | 29 |
EP1 batch: | 182 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:08:07 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:02:38 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:52:19 CEST | jreher | Updated APD location via API. |
03. Feb 2020 14:22:28 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:49:27 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:56:05 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:23:05 CET | jreher | Updated box and position via API. |
01. Oct 2019 11:32:16 CEST | spankonin | Updated APD batch assignment via API. |
05. Jul 2019 13:56:42 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:15:25 CET | Tobias | Corrected dark current unit. |
19. Sep 2018 14:05:34 CEST | Tobias | Imported from Hamamatsu datasheet. |