RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3314036259 - Archived data from Tue, 11. August 2020 18:02:30 CEST


This is all the information about APD 3314036259. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3314036259
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 384 V
Dark current: 18.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 153
Position in Box: 38
EP1 batch: 181
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.9119499 V     T = -25 °C: 348.0978222 V
Voltage for Gain 150: T = +20 °C: 390.6678351 V     T = -25 °C: 355.3569498 V
Voltage for Gain 200: T = +20 °C: 394.9625645 V     T = -25 °C: 359.4335572 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.698806663 V-1     T = -25 °C: 4.989989035 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.442962709 V-1     T = -25 °C: 9.349220453 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.84036407 V-1     T = -25 °C: 14.79847154 V-1
Break-through voltage: T = +20 °C: 409.4076038 V     T = -25 °C: 373.712232 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:08:01 CET jreher Updated box and position via API.
11. Aug 2020 18:02:30 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:15 CEST jreher Updated APD location via API.
03. Feb 2020 14:23:25 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:24 CET jreher Updated APD location via API.
27. Nov 2019 19:55:54 CET jreher Updated APD location via API.
25. Nov 2019 17:23:00 CET jreher Updated box and position via API.
01. Oct 2019 11:31:48 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:56:35 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:24 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:33 CEST Tobias Imported from Hamamatsu datasheet.