Subdetector specification:  
Serial: 3314036257
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E11
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 381 V
Dark current: 15.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 153
Position in Box: 36
EP1 batch: 181
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.8719019 V     T = -25 °C: 346.2505339 V
Voltage for Gain 150: T = +20 °C: 388.5596251 V     T = -25 °C: 353.4153682 V
Voltage for Gain 200: T = +20 °C: 392.8307471 V     T = -25 °C: 357.4378794 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.783934587 V-1     T = -25 °C: 4.967506696 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.556106775 V-1     T = -25 °C: 9.33841426 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.02693574 V-1     T = -25 °C: 16.90166443 V-1
Break-through voltage: T = +20 °C: 407.7072934 V     T = -25 °C: 371.8418668 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:08:00 CET jreher Updated box and position via API.
11. Aug 2020 18:02:29 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:15 CEST jreher Updated APD location via API.
03. Feb 2020 14:23:25 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:24 CET jreher Updated APD location via API.
27. Nov 2019 19:55:54 CET jreher Updated APD location via API.
25. Nov 2019 17:22:59 CET jreher Updated box and position via API.
01. Oct 2019 11:31:48 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:56:35 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:24 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:33 CEST Tobias Imported from Hamamatsu datasheet.