Subdetector specification:  
Serial: 3313036209
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D01
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 379 V
Dark current: 19.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 153
Position in Box: 3
EP1 batch: 180
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.3908597 V     T = -25 °C: 344.3529608 V
Voltage for Gain 150: T = +20 °C: 386.1570379 V     T = -25 °C: 351.5981212 V
Voltage for Gain 200: T = +20 °C: 390.515489 V     T = -25 °C: 355.6107775 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.556169078 V-1     T = -25 °C: 4.888500291 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.844895278 V-1     T = -25 °C: 10.12454281 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.32803205 V-1     T = -25 °C: 16.84250326 V-1
Break-through voltage: T = +20 °C: 404.9100036 V     T = -25 °C: 369.6121231 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 09:59:58 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:00:14 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:07:57 CET jreher Updated box and position via API.
11. Aug 2020 18:02:23 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:12 CEST jreher Updated APD location via API.
03. Feb 2020 14:23:45 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:21 CET jreher Updated APD location via API.
27. Nov 2019 19:55:52 CET jreher Updated APD location via API.
25. Nov 2019 17:22:57 CET jreher Updated box and position via API.
01. Oct 2019 11:31:24 CEST spankonin Updated APD batch assignment via API.
01. Oct 2019 11:30:25 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:56:32 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:22 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:32 CEST Tobias Imported from Hamamatsu datasheet.