Subdetector specification:  
Serial: 3311036089
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 386.7 V
Dark current: 16.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 151
Position in Box: 28
EP1 batch: 178
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.5998489 V     T = -25 °C: 352.277551 V
Voltage for Gain 150: T = +20 °C: 394.345493 V     T = -25 °C: 359.7984439 V
Voltage for Gain 200: T = +20 °C: 398.6484308 V     T = -25 °C: 363.8831884 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.439808124 V-1     T = -25 °C: 5.066210734 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.682486666 V-1     T = -25 °C: 9.192869252 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.53501779 V-1     T = -25 °C: 16.09690413 V-1
Break-through voltage: T = +20 °C: 413.4924566 V     T = -25 °C: 377.1594878 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:44 CET jreher Updated box and position via API.
11. Aug 2020 18:02:08 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:05 CEST jreher Updated APD location via API.
03. Feb 2020 14:24:22 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:16 CET jreher Updated APD location via API.
27. Nov 2019 19:55:31 CET jreher Updated APD location via API.
25. Nov 2019 17:22:49 CET jreher Updated box and position via API.
26. Sep 2019 15:32:32 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:56:18 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:20 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:30 CEST Tobias Imported from Hamamatsu datasheet.