Show Hamamatsu Avalanche Photo Diode 3311036039 - Archived data from Wed, 27. November 2019 19:55:21 CET


This is all the information about APD 3311036039. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3311036039
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D11
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 382.8 V
Dark current: 21.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 150
Position in Box: 35
EP1 batch: 176
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:37 CET jreher Updated box and position via API.
11. Aug 2020 18:02:00 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:52:01 CEST jreher Updated APD location via API.
03. Feb 2020 14:25:04 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:12 CET jreher Updated APD location via API.
27. Nov 2019 19:55:21 CET jreher Updated APD location via API.
25. Nov 2019 17:22:45 CET jreher Updated box and position via API.
26. Sep 2019 15:33:17 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:56:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:18 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:29 CEST Tobias Imported from Hamamatsu datasheet.