Show Hamamatsu Avalanche Photo Diode 3310035942 - Archived data from Thu, 30. January 2020 14:06:15 CET
This is all the information about APD 3310035942. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 3310035942 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Giessen |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B06 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 383.7 V |
Dark current: | 18.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 149 |
Position in Box: | 1 |
EP1 batch: | 174 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
10. Jun 2022 12:19:46 CEST | oafedulidis | Assigned to capsule by script |
03. May 2021 15:19:41 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:07:27 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:01:46 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:51:54 CEST | jreher | Updated APD location via API. |
30. Jan 2020 14:06:15 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:49:06 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:55:08 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:22:38 CET | jreher | Updated box and position via API. |
26. Sep 2019 15:34:29 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:56:01 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:15:16 CET | Tobias | Corrected dark current unit. |
19. Sep 2018 14:05:28 CEST | Tobias | Imported from Hamamatsu datasheet. |