Subdetector specification:  
Serial: 0807007722
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390.4 V
Dark current: 3.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 355
Position in Box: 21
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 91
Position in grid: 13
Arrival for irradiation: 03. Aug 2017
Sent for analysis after irradiation: 16. Aug 2017
Return for assembly: none
   
Irradiation:  
Date: 10. Aug 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 2
Bias voltage: 390.4 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.5423245 V     T = -25 °C: 354.1222426 V
Voltage for Gain 150: T = +20 °C: 398.4238186 V     T = -25 °C: 361.6745494 V
Voltage for Gain 200: T = +20 °C: 402.7822495 V     T = -25 °C: 365.9037952 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.412903031 V-1     T = -25 °C: 4.768138158 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.591036669 V-1     T = -25 °C: 9.591991184 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.95543312 V-1     T = -25 °C: 15.12056392 V-1
Break-through voltage: T = +20 °C: 419.1940488 V     T = -25 °C: 381.8576136 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 14:46:44 CEST oafedulidis Updated box and position via API.
16. Apr 2021 22:00:54 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:33:51 CET jreher Updated box and position via API.
08. Oct 2020 18:15:12 CEST jreher Updated APD location via API.
17. Aug 2020 14:26:32 CEST vwerner Updated APD batch assignment via API.
23. Aug 2017 16:05:03 CEST markus.moritz Entered shipped after irradiation date.
10. Aug 2017 15:09:14 CEST hans-georg.zaunick Entered irradiation information.
07. Aug 2017 16:57:30 CEST hans-georg.zaunick Entered arrival for irradiation date.
04. Aug 2017 03:15:21 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:24:36 CEST Tobias Imported from Hamamatsu datasheet.