Subdetector specification:  
Serial: 3306035801
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D08
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 376.9 V
Dark current: 32.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 147
Position in Box: 29
EP1 batch: 171
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.4197042 V     T = -25 °C: 344.0722935 V
Voltage for Gain 150: T = +20 °C: 384.9710467 V     T = -25 °C: 351.1569798 V
Voltage for Gain 200: T = +20 °C: 389.202673 V     T = -25 °C: 355.1383906 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.678937953 V-1     T = -25 °C: 4.761935192 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.324840445 V-1     T = -25 °C: 10.06256553 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.68044586 V-1     T = -25 °C: 14.76057783 V-1
Break-through voltage: T = +20 °C: 405.2899336 V     T = -25 °C: 369.7764921 V
   
Notes:


Version history

Time Author Change comment
20. Oct 2021 09:32:24 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:00:52 CEST jreher Updated box and position via API.
05. Feb 2021 11:07:15 CET jreher Updated box and position via API.
11. Aug 2020 18:01:32 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:48 CEST jreher Updated APD location via API.
30. Jan 2020 14:04:44 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:49:01 CET jreher Updated APD location via API.
27. Nov 2019 19:54:48 CET jreher Updated APD location via API.
25. Nov 2019 17:22:31 CET jreher Updated box and position via API.
26. Sep 2019 15:35:39 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:55:48 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:13 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:26 CEST Tobias Imported from Hamamatsu datasheet.