Subdetector specification:  
Serial: 3305035768
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C05
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.8 V
Dark current: 24.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 147
Position in Box: 6
EP1 batch: 171
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.3793538 V     T = -25 °C: 345.8804308 V
Voltage for Gain 150: T = +20 °C: 387.0562424 V     T = -25 °C: 353.0610538 V
Voltage for Gain 200: T = +20 °C: 391.3867949 V     T = -25 °C: 357.136414 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.585476195 V-1     T = -25 °C: 4.98675573 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.142598569 V-1     T = -25 °C: 8.959153121 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 16.17367376 V-1     T = -25 °C: 15.36965916 V-1
Break-through voltage: T = +20 °C: 406.1226091 V     T = -25 °C: 371.2521405 V
   
Notes:


Version history

Time Author Change comment
27. Oct 2021 14:17:48 CEST oafedulidis Assigned to capsule by script
21. Apr 2021 11:02:04 CEST jreher Updated box and position via API.
05. Feb 2021 11:07:12 CET jreher Updated box and position via API.
11. Aug 2020 18:01:28 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:46 CEST jreher Updated APD location via API.
30. Jan 2020 14:04:12 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:59 CET jreher Updated APD location via API.
27. Nov 2019 19:54:46 CET jreher Updated APD location via API.
25. Nov 2019 17:22:29 CET jreher Updated box and position via API.
26. Sep 2019 15:35:37 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:55:46 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:13 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:26 CEST Tobias Imported from Hamamatsu datasheet.