Show Hamamatsu Avalanche Photo Diode 3304035691 - Archived data from Tue, 11. August 2020 18:01:19 CEST


This is all the information about APD 3304035691. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3304035691
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.8 V
Dark current: 23.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 146
Position in Box: 14
EP1 batch: 169
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.3422577 V     T = -25 °C: 343.2796909 V
Voltage for Gain 150: T = +20 °C: 384.9785103 V     T = -25 °C: 350.3955076 V
Voltage for Gain 200: T = +20 °C: 389.2605866 V     T = -25 °C: 354.386559 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.646635059 V-1     T = -25 °C: 4.905654999 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.199314299 V-1     T = -25 °C: 9.547482184 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.33209315 V-1     T = -25 °C: 14.95558456 V-1
Break-through voltage: T = +20 °C: 404.9487874 V     T = -25 °C: 369.3102491 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:07:06 CET jreher Updated box and position via API.
11. Aug 2020 18:01:19 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:43 CEST jreher Updated APD location via API.
28. Jan 2020 16:59:05 CET vwerner Updated APD batch assignment via API.
28. Jan 2020 16:50:38 CET vwerner Updated APD batch assignment via API.
29. Nov 2019 11:48:56 CET jreher Updated APD location via API.
27. Nov 2019 19:54:36 CET jreher Updated APD location via API.
25. Nov 2019 17:22:25 CET jreher Updated box and position via API.
23. Sep 2019 17:21:27 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:55:39 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:11 CET Tobias Corrected dark current unit.
19. Sep 2018 14:05:25 CEST Tobias Imported from Hamamatsu datasheet.