Show Hamamatsu Avalanche Photo Diode 3302035607 - Archived data from Mon, 25. November 2019 17:22:20 CET
This is all the information about APD 3302035607. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 3302035607 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 145 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D04 |
Break-through voltage: | 407 V |
Voltage for Gain 100 (T=+25°C): | 378.9 V |
Dark current: | 32.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 145 |
Position in Box: | 15 |
EP1 batch: | 168 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2021 09:42:01 CET | oafedulidis | Assigned to capsule by script |
16. Jun 2021 16:02:40 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:58:58 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:51:47 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:06:58 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:01:10 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:51:38 CEST | jreher | Updated APD location via API. |
28. Jan 2020 16:32:53 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:48:52 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:54:25 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:22:20 CET | jreher | Updated box and position via API. |
23. Sep 2019 17:21:47 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:55:31 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:15:09 CET | Tobias | Corrected dark current unit. |
19. Sep 2018 14:05:23 CEST | Tobias | Imported from Hamamatsu datasheet. |