Show Hamamatsu Avalanche Photo Diode 3214035390 - Archived data from Tue, 11. August 2020 17:55:05 CEST


This is all the information about APD 3214035390. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3214035390
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G06
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 384.2 V
Dark current: 20.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 142
Position in Box: 4
EP1 batch: 164
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.9609306 V     T = -25 °C: 347.6716704 V
Voltage for Gain 150: T = +20 °C: 390.8083666 V     T = -25 °C: 355.0649613 V
Voltage for Gain 200: T = +20 °C: 395.1676429 V     T = -25 °C: 359.2308743 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.62830236 V-1     T = -25 °C: 4.675412495 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.175357873 V-1     T = -25 °C: 9.405718695 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.35043007 V-1     T = -25 °C: 14.84790407 V-1
Break-through voltage: T = +20 °C: 410.279685 V     T = -25 °C: 374.2214109 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:37:55 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:31:26 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:06:38 CET jreher Updated box and position via API.
11. Aug 2020 17:55:05 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:27 CEST jreher Updated APD location via API.
12. Dec 2019 14:41:09 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:43 CET jreher Updated APD location via API.
27. Nov 2019 19:53:54 CET jreher Updated APD location via API.
25. Nov 2019 17:22:08 CET jreher Updated box and position via API.
20. Sep 2019 18:49:47 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:55:12 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:05 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:24 CEST Tobias Imported from Hamamatsu datasheet.