Show Hamamatsu Avalanche Photo Diode 3214035373 - Archived data from Tue, 11. August 2020 17:55:01 CEST


This is all the information about APD 3214035373. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3214035373
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G05
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 384.8 V
Dark current: 18.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 141
Position in Box: 39
EP1 batch: 163
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.9529289 V     T = -25 °C: 348.3036675 V
Voltage for Gain 150: T = +20 °C: 391.7807128 V     T = -25 °C: 355.7152687 V
Voltage for Gain 200: T = +20 °C: 396.1305891 V     T = -25 °C: 359.8824136 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.597523682 V-1     T = -25 °C: 4.77667945 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.139172761 V-1     T = -25 °C: 9.637641224 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.26113428 V-1     T = -25 °C: 15.2400685 V-1
Break-through voltage: T = +20 °C: 410.7275858 V     T = -25 °C: 374.570472 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:20:58 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:15:33 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:06:33 CET jreher Updated box and position via API.
11. Aug 2020 17:55:01 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:25 CEST jreher Updated APD location via API.
12. Dec 2019 14:41:08 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:42 CET jreher Updated APD location via API.
27. Nov 2019 19:53:46 CET jreher Updated APD location via API.
25. Nov 2019 17:22:06 CET jreher Updated box and position via API.
20. Sep 2019 18:49:16 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:55:07 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:04 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:24 CEST Tobias Imported from Hamamatsu datasheet.