Serial: 3213035348
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 387.7 V
Dark current: 23.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 141
Position in Box: 26
EP1 batch: 163
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.4882315 V     T = -25 °C: 351.1594318 V
Voltage for Gain 150: T = +20 °C: 395.3694848 V     T = -25 °C: 358.6077879 V
Voltage for Gain 200: T = +20 °C: 399.727423 V     T = -25 °C: 362.7782302 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.404157719 V-1     T = -25 °C: 4.81260602 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.614687978 V-1     T = -25 °C: 9.770493182 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.04907317 V-1     T = -25 °C: 15.5654163 V-1
Break-through voltage: T = +20 °C: 415.5533813 V     T = -25 °C: 378.539889 V
   
Notes:


Version history

Time Author Change comment
25. Oct 2021 14:40:23 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:13 CEST jreher Updated box and position via API.
05. Feb 2021 11:06:32 CET jreher Updated box and position via API.
11. Aug 2020 17:54:58 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:24 CEST jreher Updated APD location via API.
12. Dec 2019 14:41:07 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:41 CET jreher Updated APD location via API.
27. Nov 2019 19:53:45 CET jreher Updated APD location via API.
25. Nov 2019 17:22:05 CET jreher Updated box and position via API.
20. Sep 2019 18:49:15 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:55:05 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:04 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:23 CEST Tobias Imported from Hamamatsu datasheet.