RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3211035257 - Archived data from Tue, 11. August 2020 17:54:46 CEST


This is all the information about APD 3211035257. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3211035257
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 385 V
Dark current: 19.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 140
Position in Box: 16
EP1 batch: 161
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 384.301605 V     T = -25 °C: 349.248419 V
Voltage for Gain 150: T = +20 °C: 392.1138251 V     T = -25 °C: 356.7808552 V
Voltage for Gain 200: T = +20 °C: 396.4575046 V     T = -25 °C: 361.0892683 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.524141556 V-1     T = -25 °C: 4.837227501 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.00712589 V-1     T = -25 °C: 9.653843571 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.94424177 V-1     T = -25 °C: 14.61414435 V-1
Break-through voltage: T = +20 °C: 413.1120857 V     T = -25 °C: 374.9167158 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:06:23 CET jreher Updated box and position via API.
11. Aug 2020 17:54:46 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:18 CEST jreher Updated APD location via API.
12. Dec 2019 14:42:33 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:36 CET jreher Updated APD location via API.
27. Nov 2019 19:53:33 CET jreher Updated APD location via API.
25. Nov 2019 17:22:00 CET jreher Updated box and position via API.
20. Sep 2019 18:48:19 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:57 CEST jreher Updated APD location via API.
03. Jan 2019 00:15:02 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:22 CEST Tobias Imported from Hamamatsu datasheet.