Subdetector specification:  
Serial: 3209035128
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 382.9 V
Dark current: 25.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 138
Position in Box: 32
EP1 batch: 158
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.7668391 V     T = -25 °C: 347.4123616 V
Voltage for Gain 150: T = +20 °C: 390.6334473 V     T = -25 °C: 354.7607456 V
Voltage for Gain 200: T = +20 °C: 394.9913536 V     T = -25 °C: 358.8798756 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.678496297 V-1     T = -25 °C: 4.810052212 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.351868752 V-1     T = -25 °C: 9.814008233 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.58026746 V-1     T = -25 °C: 15.62814539 V-1
Break-through voltage: T = +20 °C: 410.8461827 V     T = -25 °C: 374.4413124 V
   
Notes:


Version history

Time Author Change comment
15. Apr 2021 17:00:46 CEST jreher Updated box and position via API.
05. Feb 2021 11:06:08 CET jreher Updated box and position via API.
11. Aug 2020 17:54:29 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:11 CEST jreher Updated APD location via API.
09. Dec 2019 18:13:30 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:05:06 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:30 CET jreher Updated APD location via API.
27. Nov 2019 19:53:12 CET jreher Updated APD location via API.
25. Nov 2019 17:21:51 CET jreher Updated box and position via API.
20. Sep 2019 18:46:07 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:42 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:59 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:21 CEST Tobias Imported from Hamamatsu datasheet.