RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3208035086 - Archived data from Fri, 05. February 2021 11:06:06 CET


This is all the information about APD 3208035086. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3208035086
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D07
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.2 V
Dark current: 18.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 138
Position in Box: 8
EP1 batch: 158
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.1565533 V     T = -25 °C: 342.3377055 V
Voltage for Gain 150: T = +20 °C: 384.9836179 V     T = -25 °C: 349.5510706 V
Voltage for Gain 200: T = +20 °C: 389.3693398 V     T = -25 °C: 353.5933957 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.567569202 V-1     T = -25 °C: 4.897333273 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.875827788 V-1     T = -25 °C: 10.10444617 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.38235723 V-1     T = -25 °C: 16.20228057 V-1
Break-through voltage: T = +20 °C: 405.2073474 V     T = -25 °C: 368.7664735 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:25:29 CEST oafedulidis Assigned to capsule by script
28. Apr 2021 13:27:28 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:06:06 CET jreher Updated box and position via API.
11. Aug 2020 17:54:25 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:08 CEST jreher Updated APD location via API.
09. Dec 2019 18:13:48 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:05:53 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:28 CET jreher Updated APD location via API.
27. Nov 2019 19:53:10 CET jreher Updated APD location via API.
25. Nov 2019 17:21:49 CET jreher Updated box and position via API.
20. Sep 2019 18:46:05 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:40 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:58 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:20 CEST Tobias Imported from Hamamatsu datasheet.