Show Hamamatsu Avalanche Photo Diode 3208035058 - Archived data from Fri, 05. February 2021 11:06:01 CET


This is all the information about APD 3208035058. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3208035058
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C09
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.1 V
Dark current: 22 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 137
Position in Box: 37
EP1 batch: 157
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.1497479 V     T = -25 °C: 344.933501 V
Voltage for Gain 150: T = +20 °C: 388.0035057 V     T = -25 °C: 352.2900835 V
Voltage for Gain 200: T = +20 °C: 392.3751212 V     T = -25 °C: 356.4271801 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.531237399 V-1     T = -25 °C: 4.953955473 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.854640129 V-1     T = -25 °C: 9.144087156 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.38030012 V-1     T = -25 °C: 16.07270348 V-1
Break-through voltage: T = +20 °C: 407.8649084 V     T = -25 °C: 371.6627892 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 15:06:21 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:20:39 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:06:01 CET jreher Updated box and position via API.
11. Aug 2020 17:54:20 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:06 CEST jreher Updated APD location via API.
09. Dec 2019 18:14:06 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:06:52 CET spankonin Updated APD batch assignment via API.
09. Dec 2019 18:06:22 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:26 CET jreher Updated APD location via API.
27. Nov 2019 19:53:02 CET jreher Updated APD location via API.
25. Nov 2019 17:21:47 CET jreher Updated box and position via API.
20. Sep 2019 18:45:30 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:34 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:58 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:20 CEST Tobias Imported from Hamamatsu datasheet.