RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3206034960 - Archived data from Tue, 11. August 2020 18:08:25 CEST


This is all the information about APD 3206034960. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3206034960
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.6 V
Dark current: 27.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 136
Position in Box: 15
EP1 batch: 155
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 405.2073631 V     T = -25 °C: 362.2863778 V
Voltage for Gain 150: T = +20 °C: 405.2308359 V     T = -25 °C: 364.8772433 V
Voltage for Gain 200: T = +20 °C: 405.2543087 V     T = -25 °C: 366.133172 V
Gain/Voltage slope at M = 100: T = +20 °C: 2130.124904 V-1     T = -25 °C: 14.73578711 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 2130.124904 V-1     T = -25 °C: 25.97237506 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 2130.124904 V-1     T = -25 °C: 46.67838217 V-1
Break-through voltage: T = +20 °C: 405.9685682 V     T = -25 °C: 369.9238266 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:50 CET jreher Updated box and position via API.
11. Aug 2020 18:08:25 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:51:00 CEST jreher Updated APD location via API.
09. Mar 2020 17:39:25 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:21 CET jreher Updated APD location via API.
27. Nov 2019 19:52:49 CET jreher Updated APD location via API.
25. Nov 2019 17:21:40 CET jreher Updated box and position via API.
20. Sep 2019 18:44:30 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:25 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:55 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:19 CEST Tobias Imported from Hamamatsu datasheet.