RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3206034955 - Archived data from Tue, 11. August 2020 18:08:24 CEST


This is all the information about APD 3206034955. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3206034955
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D05
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 376.7 V
Dark current: 20.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 136
Position in Box: 11
EP1 batch: 154
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 404.2296858 V     T = -25 °C: 361.2630165 V
Voltage for Gain 150: T = +20 °C: 404.2370787 V     T = -25 °C: 363.4673766 V
Voltage for Gain 200: T = +20 °C: 404.2444716 V     T = -25 °C: 364.5306386 V
Gain/Voltage slope at M = 100: T = +20 °C: 6763.238559 V-1     T = -25 °C: 22.50411672 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 6763.238559 V-1     T = -25 °C: 32.93599896 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 6763.238559 V-1     T = -25 °C: 60.25528202 V-1
Break-through voltage: T = +20 °C: 404.7326581 V     T = -25 °C: 368.4141089 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:50 CET jreher Updated box and position via API.
11. Aug 2020 18:08:24 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:59 CEST jreher Updated APD location via API.
09. Mar 2020 17:39:24 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:21 CET jreher Updated APD location via API.
27. Nov 2019 19:52:48 CET jreher Updated APD location via API.
25. Nov 2019 17:21:40 CET jreher Updated box and position via API.
20. Sep 2019 18:43:39 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:24 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:55 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:19 CEST Tobias Imported from Hamamatsu datasheet.