RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3205034891 - Archived data from Tue, 11. August 2020 18:08:16 CEST


This is all the information about APD 3205034891. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3205034891
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E06
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.3 V
Dark current: 21.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 135
Position in Box: 19
EP1 batch: 153
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.3499373 V     T = -25 °C: 348.5652216 V
Voltage for Gain 150: T = +20 °C: 391.2600244 V     T = -25 °C: 355.8516924 V
Voltage for Gain 200: T = +20 °C: 395.6508898 V     T = -25 °C: 359.8837782 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.572426413 V-1     T = -25 °C: 4.967388212 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.71079369 V-1     T = -25 °C: 10.00793185 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.33253278 V-1     T = -25 °C: 15.23704283 V-1
Break-through voltage: T = +20 °C: 411.3943289 V     T = -25 °C: 374.4506453 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:43 CET jreher Updated box and position via API.
11. Aug 2020 18:08:16 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:56 CEST jreher Updated APD location via API.
09. Mar 2020 17:39:01 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:18 CET jreher Updated APD location via API.
27. Nov 2019 19:52:38 CET jreher Updated APD location via API.
25. Nov 2019 17:21:36 CET jreher Updated box and position via API.
20. Sep 2019 18:42:42 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:17 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:53 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:18 CEST Tobias Imported from Hamamatsu datasheet.