RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3204034863 - Archived data from Tue, 11. August 2020 18:08:14 CEST


This is all the information about APD 3204034863. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3204034863
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 388.7 V
Dark current: 23.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 135
Position in Box: 9
EP1 batch: 153
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.5959334 V     T = -25 °C: 353.5776607 V
Voltage for Gain 150: T = +20 °C: 397.3148543 V     T = -25 °C: 361.0232258 V
Voltage for Gain 200: T = +20 °C: 401.6238743 V     T = -25 °C: 365.1998542 V
Gain/Voltage slope at M = 100: T = +20 °C: 3.964729823 V-1     T = -25 °C: 4.671172831 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.818645217 V-1     T = -25 °C: 9.410123722 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 16.15339438 V-1     T = -25 °C: 14.78504132 V-1
Break-through voltage: T = +20 °C: 414.6658107 V     T = -25 °C: 378.3954808 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:42 CET jreher Updated box and position via API.
11. Aug 2020 18:08:14 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:55 CEST jreher Updated APD location via API.
09. Mar 2020 17:39:00 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:17 CET jreher Updated APD location via API.
27. Nov 2019 19:52:37 CET jreher Updated APD location via API.
25. Nov 2019 17:21:35 CET jreher Updated box and position via API.
20. Sep 2019 18:42:41 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:54:16 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:53 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:18 CEST Tobias Imported from Hamamatsu datasheet.