Subdetector specification:  
Serial: 3204034847
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 387.1 V
Dark current: 22.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 134
Position in Box: 46
EP1 batch: 152
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.0549464 V     T = -25 °C: 352.0631898 V
Voltage for Gain 150: T = +20 °C: 395.8544327 V     T = -25 °C: 359.5494538 V
Voltage for Gain 200: T = +20 °C: 400.1877902 V     T = -25 °C: 363.7407466 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.613863472 V-1     T = -25 °C: 4.836181461 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.142076356 V-1     T = -25 °C: 9.804356763 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.3142416 V-1     T = -25 °C: 15.43868975 V-1
Break-through voltage: T = +20 °C: 414.5572761 V     T = -25 °C: 378.0458953 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:38 CET jreher Updated box and position via API.
11. Aug 2020 18:08:11 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:54 CEST jreher Updated APD location via API.
09. Mar 2020 17:38:38 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:16 CET jreher Updated APD location via API.
27. Nov 2019 19:52:29 CET jreher Updated APD location via API.
25. Nov 2019 17:21:33 CET jreher Updated box and position via API.
17. Sep 2019 12:07:23 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:54:11 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:53 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:17 CEST Tobias Imported from Hamamatsu datasheet.