RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3204034841 - Archived data from Tue, 11. August 2020 18:08:10 CEST


This is all the information about APD 3204034841. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3204034841
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 380.6 V
Dark current: 21.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 134
Position in Box: 41
EP1 batch: 152
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.1965471 V     T = -25 °C: 345.7014347 V
Voltage for Gain 150: T = +20 °C: 388.9957969 V     T = -25 °C: 353.0130708 V
Voltage for Gain 200: T = +20 °C: 393.3377663 V     T = -25 °C: 357.1112418 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.591239561 V-1     T = -25 °C: 4.752807876 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.042088554 V-1     T = -25 °C: 9.596947927 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.11667646 V-1     T = -25 °C: 15.27086301 V-1
Break-through voltage: T = +20 °C: 408.8607149 V     T = -25 °C: 372.277935 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:22:10 CET jreher Assigned to capsule by script
05. Feb 2021 11:05:37 CET jreher Updated box and position via API.
18. Dec 2020 14:00:18 CET jreher Updated box and position via API.
11. Aug 2020 18:08:10 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:53 CEST jreher Updated APD location via API.
09. Mar 2020 17:38:38 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:16 CET jreher Updated APD location via API.
27. Nov 2019 19:52:28 CET jreher Updated APD location via API.
25. Nov 2019 17:21:33 CET jreher Updated box and position via API.
17. Sep 2019 12:07:23 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:54:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:52 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:17 CEST Tobias Imported from Hamamatsu datasheet.