RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3116034736 - Archived data from Fri, 05. February 2021 11:05:22 CET


This is all the information about APD 3116034736. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3116034736
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 378.2 V
Dark current: 13.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 132
Position in Box: 15
EP1 batch: 149
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.9532892 V     T = -25 °C: 343.1314608 V
Voltage for Gain 150: T = +20 °C: 385.7508172 V     T = -25 °C: 350.3633213 V
Voltage for Gain 200: T = +20 °C: 390.0884672 V     T = -25 °C: 354.4282664 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.658539833 V-1     T = -25 °C: 4.978145056 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.229703165 V-1     T = -25 °C: 9.302804931 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.42082855 V-1     T = -25 °C: 16.74619636 V-1
Break-through voltage: T = +20 °C: 405.517977 V     T = -25 °C: 369.4021293 V
   
Notes:


Version history

Time Author Change comment
16. May 2022 13:33:10 CEST oafedulidis Updated box and position via API.
28. Apr 2021 13:29:32 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:05:22 CET jreher Updated box and position via API.
11. Aug 2020 17:54:06 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:44 CEST jreher Updated APD location via API.
09. Dec 2019 18:15:30 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:08 CET jreher Updated APD location via API.
27. Nov 2019 19:52:06 CET jreher Updated APD location via API.
25. Nov 2019 17:21:24 CET jreher Updated box and position via API.
17. Sep 2019 12:08:20 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:53:57 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:50 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:15 CEST Tobias Imported from Hamamatsu datasheet.