RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3114034663 - Archived data from Thu, 15. April 2021 17:01:30 CEST


This is all the information about APD 3114034663. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3114034663
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 375.8 V
Dark current: 17.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 131
Position in Box: 9
EP1 batch: 147
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.0129808 V     T = -25 °C: 341.3950672 V
Voltage for Gain 150: T = +20 °C: 383.7964865 V     T = -25 °C: 348.6292275 V
Voltage for Gain 200: T = +20 °C: 388.1270474 V     T = -25 °C: 352.6782318 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.650520752 V-1     T = -25 °C: 4.902666409 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.252938087 V-1     T = -25 °C: 10.14695311 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.47078788 V-1     T = -25 °C: 16.3184187 V-1
Break-through voltage: T = +20 °C: 402.947022 V     T = -25 °C: 367.1582744 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:09:32 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:30 CEST jreher Updated box and position via API.
05. Feb 2021 11:05:14 CET jreher Updated box and position via API.
11. Aug 2020 17:53:55 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:39 CEST jreher Updated APD location via API.
09. Dec 2019 18:16:50 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:48:04 CET jreher Updated APD location via API.
27. Nov 2019 19:51:55 CET jreher Updated APD location via API.
25. Nov 2019 17:21:19 CET jreher Updated box and position via API.
17. Sep 2019 11:37:11 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:53:48 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:48 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:14 CEST Tobias Imported from Hamamatsu datasheet.