Subdetector specification:  
Serial: 3112034570
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 402 V
Voltage for Gain 100 (T=+25°C): 373.4 V
Dark current: 13.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 129
Position in Box: 39
EP1 batch: 145
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.1945432 V     T = -25 °C: 338.2338204 V
Voltage for Gain 150: T = +20 °C: 395.8638036 V     T = -25 °C: 345.6365236 V
Voltage for Gain 200: T = +20 °C: 397.2763647 V     T = -25 °C: 349.8051675 V
Gain/Voltage slope at M = 100: T = +20 °C: 12.80517796 V-1     T = -25 °C: 4.832049959 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 24.84837085 V-1     T = -25 °C: 9.764050112 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 41.12488618 V-1     T = -25 °C: 15.34547553 V-1
Break-through voltage: T = +20 °C: 401.5073231 V     T = -25 °C: 365.4631232 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:05:03 CET jreher Updated box and position via API.
11. Aug 2020 18:08:00 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:32 CEST jreher Updated APD location via API.
06. Mar 2020 13:56:15 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:59 CET jreher Updated APD location via API.
27. Nov 2019 19:51:35 CET jreher Updated APD location via API.
25. Nov 2019 17:21:12 CET jreher Updated box and position via API.
03. Sep 2019 11:34:25 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:35 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:46 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:13 CEST Tobias Imported from Hamamatsu datasheet.