RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3110034507 - Archived data from Wed, 01. December 2021 12:56:25 CET


This is all the information about APD 3110034507. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3110034507
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C10
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 375.3 V
Dark current: 19.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 128
Position in Box: 50
EP1 batch: 143
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.3318456 V     T = -25 °C: 340.8271196 V
Voltage for Gain 150: T = +20 °C: 383.1335316 V     T = -25 °C: 348.0177401 V
Voltage for Gain 200: T = +20 °C: 387.5089805 V     T = -25 °C: 352.0645326 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.551537112 V-1     T = -25 °C: 5.142379049 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.899051062 V-1     T = -25 °C: 9.740832929 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.51876849 V-1     T = -25 °C: 15.48632466 V-1
Break-through voltage: T = +20 °C: 403.4523966 V     T = -25 °C: 367.418621 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 12:55:03 CET oafedulidis Assigned to capsule by script
01. Dec 2021 12:56:25 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:04:56 CET jreher Updated box and position via API.
11. Aug 2020 17:53:53 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:29 CEST jreher Updated APD location via API.
09. Dec 2019 18:16:49 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:56 CET jreher Updated APD location via API.
27. Nov 2019 19:51:25 CET jreher Updated APD location via API.
25. Nov 2019 17:21:08 CET jreher Updated box and position via API.
03. Sep 2019 11:33:37 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:28 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:44 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:12 CEST Tobias Imported from Hamamatsu datasheet.