Subdetector specification:  
Serial: 3109034457
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C11
Break-through voltage: 402 V
Voltage for Gain 100 (T=+25°C): 373.7 V
Dark current: 23.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 128
Position in Box: 12
EP1 batch: 142
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 374.4091733 V     T = -25 °C: 340.2607872 V
Voltage for Gain 150: T = +20 °C: 382.1921836 V     T = -25 °C: 347.4630668 V
Voltage for Gain 200: T = +20 °C: 386.5466457 V     T = -25 °C: 351.4160334 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.538082481 V-1     T = -25 °C: 4.654153599 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.811157433 V-1     T = -25 °C: 8.155480497 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.33090267 V-1     T = -25 °C: 17.88169119 V-1
Break-through voltage: T = +20 °C: 401.3595513 V     T = -25 °C: 365.4579712 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 10:46:46 CET oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:25 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:38 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:19 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:04:52 CET jreher Updated box and position via API.
11. Aug 2020 17:53:46 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:25 CEST jreher Updated APD location via API.
09. Dec 2019 18:17:19 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:53 CET jreher Updated APD location via API.
27. Nov 2019 19:51:22 CET jreher Updated APD location via API.
25. Nov 2019 17:21:05 CET jreher Updated box and position via API.
03. Sep 2019 11:33:12 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:25 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:43 CET Tobias Corrected dark current unit.
14. Aug 2018 16:04:10 CEST Tobias Imported from Hamamatsu datasheet.