RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3109034440 - Archived data from Tue, 11. August 2020 17:53:43 CEST


This is all the information about APD 3109034440. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3109034440
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D03
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 377.3 V
Dark current: 20.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 127
Position in Box: 49
EP1 batch: 142
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.2505101 V     T = -25 °C: 342.6738796 V
Voltage for Gain 150: T = +20 °C: 385.077886 V     T = -25 °C: 349.914933 V
Voltage for Gain 200: T = +20 °C: 389.4523988 V     T = -25 °C: 353.9928809 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.52935684 V-1     T = -25 °C: 5.152176022 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.859263519 V-1     T = -25 °C: 9.662444149 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.39612685 V-1     T = -25 °C: 15.32857243 V-1
Break-through voltage: T = +20 °C: 404.5922723 V     T = -25 °C: 368.6658413 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:49 CET jreher Updated box and position via API.
11. Aug 2020 17:53:43 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:24 CEST jreher Updated APD location via API.
09. Dec 2019 18:17:52 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:52 CET jreher Updated APD location via API.
27. Nov 2019 19:51:14 CET jreher Updated APD location via API.
25. Nov 2019 17:21:03 CET jreher Updated box and position via API.
03. Sep 2019 11:33:11 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:20 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:42 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:59 CEST Tobias Imported from Hamamatsu datasheet.