RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3108034398 - Archived data from Tue, 11. August 2020 17:53:38 CEST


This is all the information about APD 3108034398. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3108034398
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 375.5 V
Dark current: 20.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 127
Position in Box: 27
EP1 batch: 141
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.7561988 V     T = -25 °C: 340.9136432 V
Voltage for Gain 150: T = +20 °C: 383.5460802 V     T = -25 °C: 348.1607388 V
Voltage for Gain 200: T = +20 °C: 387.8797401 V     T = -25 °C: 352.2435758 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.738723218 V-1     T = -25 °C: 5.054038963 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.403409812 V-1     T = -25 °C: 9.477434027 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.74602155 V-1     T = -25 °C: 14.94716623 V-1
Break-through voltage: T = +20 °C: 402.976008 V     T = -25 °C: 367.0085119 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:46 CET jreher Updated box and position via API.
11. Aug 2020 17:53:38 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:22 CEST jreher Updated APD location via API.
09. Dec 2019 18:17:50 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:51 CET jreher Updated APD location via API.
27. Nov 2019 19:51:12 CET jreher Updated APD location via API.
25. Nov 2019 17:21:01 CET jreher Updated box and position via API.
03. Sep 2019 11:32:44 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:18 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:42 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:59 CEST Tobias Imported from Hamamatsu datasheet.