RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3107034343 - Archived data from Fri, 05. February 2021 11:04:40 CET


This is all the information about APD 3107034343. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3107034343
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 378.2 V
Dark current: 20 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 126
Position in Box: 36
EP1 batch: 140
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.1307873 V     T = -25 °C: 343.2217297 V
Voltage for Gain 150: T = +20 °C: 385.9220909 V     T = -25 °C: 350.4835822 V
Voltage for Gain 200: T = +20 °C: 390.2591197 V     T = -25 °C: 354.5640001 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.584792165 V-1     T = -25 °C: 4.932784425 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.154521419 V-1     T = -25 °C: 9.193330471 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.22692827 V-1     T = -25 °C: 16.47672101 V-1
Break-through voltage: T = +20 °C: 405.5498607 V     T = -25 °C: 369.5136909 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 15:12:37 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:20:25 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:04:40 CET jreher Updated box and position via API.
11. Aug 2020 17:53:30 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:18 CEST jreher Updated APD location via API.
09. Dec 2019 18:19:01 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:48 CET jreher Updated APD location via API.
27. Nov 2019 19:51:02 CET jreher Updated APD location via API.
25. Nov 2019 17:20:57 CET jreher Updated box and position via API.
03. Sep 2019 11:32:17 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:10 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:40 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:58 CEST Tobias Imported from Hamamatsu datasheet.