RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3106034294 - Archived data from Thu, 15. April 2021 17:01:05 CEST


This is all the information about APD 3106034294. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3106034294
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C02
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 380 V
Dark current: 15.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 126
Position in Box: 6
EP1 batch: 139
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.2423868 V     T = -25 °C: 344.3240681 V
Voltage for Gain 150: T = +20 °C: 387.0715224 V     T = -25 °C: 351.6552726 V
Voltage for Gain 200: T = +20 °C: 391.4353965 V     T = -25 °C: 355.7722935 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.532329858 V-1     T = -25 °C: 4.85536991 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.932129507 V-1     T = -25 °C: 9.902825904 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.60663771 V-1     T = -25 °C: 15.77463561 V-1
Break-through voltage: T = +20 °C: 405.2291793 V     T = -25 °C: 369.9305095 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 19:46:17 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:01:05 CEST jreher Updated box and position via API.
05. Feb 2021 11:04:36 CET jreher Updated box and position via API.
11. Aug 2020 17:53:24 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:15 CEST jreher Updated APD location via API.
09. Dec 2019 18:19:37 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:45 CET jreher Updated APD location via API.
27. Nov 2019 19:51:00 CET jreher Updated APD location via API.
25. Nov 2019 17:20:55 CET jreher Updated box and position via API.
03. Sep 2019 11:31:50 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:08 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:39 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:58 CEST Tobias Imported from Hamamatsu datasheet.