RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3106034290 - Archived data from Fri, 05. February 2021 11:04:36 CET


This is all the information about APD 3106034290. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3106034290
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 377.9 V
Dark current: 16 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 126
Position in Box: 2
EP1 batch: 139
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.8970926 V     T = -25 °C: 342.5350687 V
Voltage for Gain 150: T = +20 °C: 384.7595112 V     T = -25 °C: 349.7547315 V
Voltage for Gain 200: T = +20 °C: 389.1463081 V     T = -25 °C: 353.8095948 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.609537764 V-1     T = -25 °C: 4.794739469 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.063486897 V-1     T = -25 °C: 9.847301943 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.05942508 V-1     T = -25 °C: 15.79158364 V-1
Break-through voltage: T = +20 °C: 404.3972987 V     T = -25 °C: 368.6064132 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 19:18:53 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:18 CET jreher Updated box and position via API.
05. Feb 2021 11:04:36 CET jreher Updated box and position via API.
11. Aug 2020 17:53:23 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:15 CEST jreher Updated APD location via API.
09. Dec 2019 18:19:37 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:45 CET jreher Updated APD location via API.
27. Nov 2019 19:50:59 CET jreher Updated APD location via API.
25. Nov 2019 17:20:54 CET jreher Updated box and position via API.
03. Sep 2019 11:31:50 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:08 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:39 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:58 CEST Tobias Imported from Hamamatsu datasheet.