RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3106034239 - Archived data from Fri, 05. February 2021 11:04:28 CET


This is all the information about APD 3106034239. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3106034239
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G06
Break-through voltage: 405 V
Voltage for Gain 100 (T=+25°C): 377.6 V
Dark current: 14.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 125
Position in Box: 5
EP1 batch: 137
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.9035015 V     T = -25 °C: 342.2061936 V
Voltage for Gain 150: T = +20 °C: 384.6866495 V     T = -25 °C: 349.4429164 V
Voltage for Gain 200: T = +20 °C: 389.0077014 V     T = -25 °C: 353.5089258 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.700971746 V-1     T = -25 °C: 4.938084547 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.350113763 V-1     T = -25 °C: 9.258385396 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.66427248 V-1     T = -25 °C: 16.56628543 V-1
Break-through voltage: T = +20 °C: 404.0235804 V     T = -25 °C: 368.1147732 V
   
Notes:


Version history

Time Author Change comment
17. Jun 2021 19:10:08 CEST oafedulidis Assigned to capsule by script
15. Apr 2021 17:00:40 CEST jreher Updated box and position via API.
05. Feb 2021 11:04:28 CET jreher Updated box and position via API.
11. Aug 2020 17:53:13 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:11 CEST jreher Updated APD location via API.
09. Dec 2019 18:20:00 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:42 CET jreher Updated APD location via API.
27. Nov 2019 19:50:49 CET jreher Updated APD location via API.
25. Nov 2019 17:20:50 CET jreher Updated box and position via API.
03. Sep 2019 11:31:07 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:53:00 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:38 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:57 CEST Tobias Imported from Hamamatsu datasheet.