RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3105034220 - Archived data from Fri, 05. February 2021 11:04:25 CET


This is all the information about APD 3105034220. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3105034220
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.6 V
Dark current: 21.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 124
Position in Box: 44
EP1 batch: 137
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.08184 V     T = -25 °C: 344.7101682 V
Voltage for Gain 150: T = +20 °C: 387.9897677 V     T = -25 °C: 351.948433 V
Voltage for Gain 200: T = +20 °C: 392.3531039 V     T = -25 °C: 356.0407126 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.321981057 V-1     T = -25 °C: 5.057931069 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.479096484 V-1     T = -25 °C: 9.576055344 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.58833393 V-1     T = -25 °C: 15.43283042 V-1
Break-through voltage: T = +20 °C: 407.8108931 V     T = -25 °C: 371.1853693 V
   
Notes:


Version history

Time Author Change comment
29. Apr 2021 17:05:46 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:28:36 CET jreher Updated box and position via API.
05. Feb 2021 11:04:25 CET jreher Updated box and position via API.
11. Aug 2020 18:07:52 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:10 CEST jreher Updated APD location via API.
06. Mar 2020 13:55:16 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:41 CET jreher Updated APD location via API.
27. Nov 2019 19:50:41 CET jreher Updated APD location via API.
25. Nov 2019 17:20:48 CET jreher Updated box and position via API.
03. Sep 2019 11:31:06 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:55 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:37 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:56 CEST Tobias Imported from Hamamatsu datasheet.