Show Hamamatsu Avalanche Photo Diode 3105034218 - Archived data from Tue, 11. August 2020 18:07:52 CEST


This is all the information about APD 3105034218. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3105034218
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E09
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379 V
Dark current: 17.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 124
Position in Box: 43
EP1 batch: 137
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.5047469 V     T = -25 °C: 344.1495022 V
Voltage for Gain 150: T = +20 °C: 387.3747447 V     T = -25 °C: 351.3865689 V
Voltage for Gain 200: T = +20 °C: 391.7193527 V     T = -25 °C: 355.4760908 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.703107525 V-1     T = -25 °C: 4.925057114 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.986882016 V-1     T = -25 °C: 9.302241765 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.98670774 V-1     T = -25 °C: 16.96462011 V-1
Break-through voltage: T = +20 °C: 407.1783529 V     T = -25 °C: 370.6854503 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:25 CET jreher Updated box and position via API.
11. Aug 2020 18:07:52 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:10 CEST jreher Updated APD location via API.
06. Mar 2020 13:55:16 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:41 CET jreher Updated APD location via API.
27. Nov 2019 19:50:41 CET jreher Updated APD location via API.
25. Nov 2019 17:20:48 CET jreher Updated box and position via API.
03. Sep 2019 11:31:06 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:55 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:37 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:56 CEST Tobias Imported from Hamamatsu datasheet.