RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3105034164 - Archived data from Tue, 11. August 2020 18:07:44 CEST


This is all the information about APD 3105034164. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3105034164
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B11
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 382.2 V
Dark current: 23.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 123
Position in Box: 46
EP1 batch: 135
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.6998887 V     T = -25 °C: 347.8731885 V
Voltage for Gain 150: T = +20 °C: 391.3700138 V     T = -25 °C: 355.2649786 V
Voltage for Gain 200: T = +20 °C: 395.613174 V     T = -25 °C: 359.4120199 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.868040959 V-1     T = -25 °C: 4.961091146 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.022994431 V-1     T = -25 °C: 9.177629461 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.19224585 V-1     T = -25 °C: 16.45109163 V-1
Break-through voltage: T = +20 °C: 408.4663956 V     T = -25 °C: 372.9187023 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:17 CET jreher Updated box and position via API.
11. Aug 2020 18:07:44 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:05 CEST jreher Updated APD location via API.
06. Mar 2020 13:54:41 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:37 CET jreher Updated APD location via API.
27. Nov 2019 19:50:30 CET jreher Updated APD location via API.
25. Nov 2019 17:20:43 CET jreher Updated box and position via API.
30. Aug 2019 11:31:26 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:47 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:36 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:56 CEST Tobias Imported from Hamamatsu datasheet.