Subdetector specification:  
Serial: 3104034111
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 375.6 V
Dark current: 14.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 123
Position in Box: 19
EP1 batch: 134
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 375.3081914 V     T = -25 °C: 340.7694871 V
Voltage for Gain 150: T = +20 °C: 383.1039584 V     T = -25 °C: 347.9605213 V
Voltage for Gain 200: T = +20 °C: 387.472169 V     T = -25 °C: 352.0065976 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.528565115 V-1     T = -25 °C: 5.132131311 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.77052301 V-1     T = -25 °C: 9.60014756 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.12704477 V-1     T = -25 °C: 15.21071712 V-1
Break-through voltage: T = +20 °C: 403.2173718 V     T = -25 °C: 367.093825 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:13:03 CET oafedulidis Assigned to capsule by script
01. Dec 2021 12:57:21 CET oafedulidis Updated box and position via API.
05. Feb 2021 11:04:14 CET jreher Updated box and position via API.
11. Aug 2020 18:07:38 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:03 CEST jreher Updated APD location via API.
06. Mar 2020 13:54:17 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:35 CET jreher Updated APD location via API.
27. Nov 2019 19:50:28 CET jreher Updated APD location via API.
25. Nov 2019 17:20:41 CET jreher Updated box and position via API.
30. Aug 2019 11:30:48 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:45 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:35 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:55 CEST Tobias Imported from Hamamatsu datasheet.