RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 3104034100 - Archived data from Tue, 11. August 2020 18:07:37 CEST


This is all the information about APD 3104034100. If it is wrong, edit the data.

Subdetector specification:  
Serial: 3104034100
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D14
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 384.4 V
Dark current: 19.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 123
Position in Box: 9
EP1 batch: 134
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.0902349 V     T = -25 °C: 349.4196203 V
Voltage for Gain 150: T = +20 °C: 392.8966554 V     T = -25 °C: 356.8614874 V
Voltage for Gain 200: T = +20 °C: 397.2376113 V     T = -25 °C: 361.0418637 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.57659098 V-1     T = -25 °C: 4.766841679 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.107403433 V-1     T = -25 °C: 9.515385667 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.19781303 V-1     T = -25 °C: 14.97003166 V-1
Break-through voltage: T = +20 °C: 411.7708453 V     T = -25 °C: 375.6806579 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:13 CET jreher Updated box and position via API.
11. Aug 2020 18:07:37 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:50:02 CEST jreher Updated APD location via API.
06. Mar 2020 13:54:16 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:34 CET jreher Updated APD location via API.
27. Nov 2019 19:50:27 CET jreher Updated APD location via API.
25. Nov 2019 17:20:41 CET jreher Updated box and position via API.
30. Aug 2019 11:30:47 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:44 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:34 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:55 CEST Tobias Imported from Hamamatsu datasheet.