Subdetector specification:  
Serial: 3103034036
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D07
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 382.8 V
Dark current: 15.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 122
Position in Box: 14
EP1 batch: 132
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.4229101 V     T = -25 °C: 347.906738 V
Voltage for Gain 150: T = +20 °C: 391.2934634 V     T = -25 °C: 355.1883393 V
Voltage for Gain 200: T = +20 °C: 395.655429 V     T = -25 °C: 359.2866094 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.461917005 V-1     T = -25 °C: 5.026836259 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.70901642 V-1     T = -25 °C: 9.431649081 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.14878522 V-1     T = -25 °C: 14.88287318 V-1
Break-through voltage: T = +20 °C: 411.2691199 V     T = -25 °C: 374.4033438 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:38:00 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:31:29 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:04:06 CET jreher Updated box and position via API.
11. Aug 2020 18:00:45 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:58 CEST jreher Updated APD location via API.
28. Jan 2020 16:13:56 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:31 CET jreher Updated APD location via API.
27. Nov 2019 19:50:16 CET jreher Updated APD location via API.
25. Nov 2019 17:20:36 CET jreher Updated box and position via API.
30. Aug 2019 11:29:34 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:37 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:33 CET Tobias Corrected dark current unit.