Subdetector specification:  
Serial: 3103034034
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.3 V
Dark current: 13.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 122
Position in Box: 12
EP1 batch: 132
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.5399061 V     T = -25 °C: 347.005551 V
Voltage for Gain 150: T = +20 °C: 390.3756008 V     T = -25 °C: 354.2874819 V
Voltage for Gain 200: T = +20 °C: 394.7209699 V     T = -25 °C: 358.3845575 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.436274186 V-1     T = -25 °C: 4.989859005 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.663307046 V-1     T = -25 °C: 9.352431496 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.10064201 V-1     T = -25 °C: 14.74814937 V-1
Break-through voltage: T = +20 °C: 410.6250189 V     T = -25 °C: 373.8808104 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:04:06 CET jreher Updated box and position via API.
11. Aug 2020 18:00:45 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:49:58 CEST jreher Updated APD location via API.
28. Jan 2020 16:13:55 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:47:31 CET jreher Updated APD location via API.
27. Nov 2019 19:50:16 CET jreher Updated APD location via API.
25. Nov 2019 17:20:36 CET jreher Updated box and position via API.
30. Aug 2019 11:29:33 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 13:52:37 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:33 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:54 CEST Tobias Imported from Hamamatsu datasheet.