Show Hamamatsu Avalanche Photo Diode 3101033875 - Archived data from Tue, 11. August 2020 18:07:30 CEST
This is all the information about APD 3101033875. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 3101033875 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D05 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 384 V |
Dark current: | 16.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 120 |
Position in Box: | 25 |
EP1 batch: | 130 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 383.8177187 V T = -25 °C: 348.303718 V |
Voltage for Gain 150: | T = +20 °C: 391.6646541 V T = -25 °C: 355.6085467 V |
Voltage for Gain 200: | T = +20 °C: 396.019575 V T = -25 °C: 359.7183364 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.659585272 V-1 T = -25 °C: 4.819777334 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.24633208 V-1 T = -25 °C: 9.885406017 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.42397731 V-1 T = -25 °C: 15.84281968 V-1 |
Break-through voltage: | T = +20 °C: 411.1551016 V T = -25 °C: 374.6423364 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
17. Jun 2021 19:35:40 CEST | oafedulidis | Assigned to capsule by script |
15. Apr 2021 16:57:59 CEST | jreher | Updated box and position via API. |
05. Feb 2021 11:03:52 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:07:30 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:49:50 CEST | jreher | Updated APD location via API. |
02. Mar 2020 16:45:57 CET | vwerner | Updated APD batch assignment via API. |
29. Nov 2019 11:47:24 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:49:55 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:20:27 CET | jreher | Updated box and position via API. |
30. Aug 2019 11:25:27 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:52:21 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:14:30 CET | Tobias | Corrected dark current unit. |
06. Jul 2018 22:38:53 CEST | Tobias | Imported from Hamamatsu datasheet. |