Show Hamamatsu Avalanche Photo Diode 3008033714 - Archived data from Tue, 11. August 2020 18:07:07 CEST
This is all the information about APD 3008033714. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 3008033714 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D02 |
Break-through voltage: | 421 V |
Voltage for Gain 100 (T=+25°C): | 392.7 V |
Dark current: | 20.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 118 |
Position in Box: | 6 |
EP1 batch: | 126 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.9255312 V T = -25 °C: 356.0561242 V |
Voltage for Gain 150: | T = +20 °C: 399.8256982 V T = -25 °C: 363.5308795 V |
Voltage for Gain 200: | T = +20 °C: 404.2204617 V T = -25 °C: 367.7236226 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.509486933 V-1 T = -25 °C: 5.047259323 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.957349764 V-1 T = -25 °C: 9.85502019 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.89688183 V-1 T = -25 °C: 15.53085632 V-1 |
Break-through voltage: | T = +20 °C: 419.7082537 V T = -25 °C: 383.149136 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:03:35 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:07:07 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:49:39 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:33:47 CEST | jreher | Updated APD batch assignment via API. |
21. Jul 2020 14:33:19 CEST | jreher | Updated APD batch assignment via API. |
02. Mar 2020 16:15:18 CET | vwerner | Updated APD batch assignment via API. |
29. Nov 2019 11:47:15 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:49:31 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:20:16 CET | jreher | Updated box and position via API. |
30. Aug 2019 11:28:10 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:52:04 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:14:27 CET | Tobias | Corrected dark current unit. |
06. Jul 2018 22:38:51 CEST | Tobias | Imported from Hamamatsu datasheet. |