Show Hamamatsu Avalanche Photo Diode 3008033711 - Archived data from Tue, 11. August 2020 18:07:06 CEST
This is all the information about APD 3008033711. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 3008033711 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D03 |
Break-through voltage: | 420 V |
Voltage for Gain 100 (T=+25°C): | 392.1 V |
Dark current: | 17.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 118 |
Position in Box: | 5 |
EP1 batch: | 126 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.4823537 V T = -25 °C: 355.3682949 V |
Voltage for Gain 150: | T = +20 °C: 399.3654571 V T = -25 °C: 362.8743936 V |
Voltage for Gain 200: | T = +20 °C: 403.7354117 V T = -25 °C: 367.1264116 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.41809339 V-1 T = -25 °C: 4.698473594 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.556130039 V-1 T = -25 °C: 9.218818785 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.82682553 V-1 T = -25 °C: 14.55869152 V-1 |
Break-through voltage: | T = +20 °C: 419.3414484 V T = -25 °C: 382.7748169 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:03:35 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:07:06 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:49:39 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:33:47 CEST | jreher | Updated APD batch assignment via API. |
21. Jul 2020 14:33:19 CEST | jreher | Updated APD batch assignment via API. |
02. Mar 2020 16:15:18 CET | vwerner | Updated APD batch assignment via API. |
29. Nov 2019 11:47:15 CET | jreher | Updated APD location via API. |
27. Nov 2019 19:49:31 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:20:16 CET | jreher | Updated box and position via API. |
30. Aug 2019 11:28:09 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Jul 2019 13:52:04 CEST | jreher | Updated APD location via API. |
03. Jan 2019 00:14:27 CET | Tobias | Corrected dark current unit. |
06. Jul 2018 22:38:51 CEST | Tobias | Imported from Hamamatsu datasheet. |