Subdetector specification:  
Serial: 3008033700
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G05
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 391.9 V
Dark current: 21.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 117
Position in Box: 46
EP1 batch: 125
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
16. Apr 2021 22:10:01 CEST jreher Updated APD characteristics via API.
30. Mar 2021 15:07:19 CEST jreher Updated APD batch assignment via API.
05. Feb 2021 11:03:32 CET jreher Updated box and position via API.
03. Feb 2021 18:08:26 CET jreher Updated APD location via API.
11. Aug 2020 17:49:38 CEST jreher Updated APD location via API.
29. Nov 2019 11:47:15 CET jreher Updated APD location via API.
27. Nov 2019 19:49:23 CET jreher Updated APD location via API.
25. Nov 2019 17:20:15 CET jreher Updated box and position via API.
27. Aug 2019 12:01:48 CEST jgrochowski Updated APD batch assignment via API.
05. Jul 2019 13:51:59 CEST jreher Updated APD location via API.
03. Jan 2019 00:14:26 CET Tobias Corrected dark current unit.
06. Jul 2018 22:38:50 CEST Tobias Imported from Hamamatsu datasheet.